State Coalition for Remediation of Drycleaners Site Profiles
Stuart Cleaners & Tailors, Stuart, Florida
Description
|
This is an active perchloroethylene (PCE) drycleaning facility that began operation in 1978. The facility is located in a stand-alone building in a mixed commercial/residential setting. A small creek, which drains to the Indian River Lagoon is located approximately 100 ft north and hydraulically downgradient of the facility. The contaminant source area at the site is near the rear door (service entrance) of the facility. |
Contaminants
Contaminants present and the highest amount
detected in both soil and groundwater.
Contaminant | Media | Concentration (ppb) | Nondetect |
---|---|---|---|
Tetrachloroethene (PCE) | groundwater | 1,600 ppb | |
Tetrachloroethene (PCE) | soil | 3,300 ppb |
Site Hydrology
Deepest Significant Groundwater Contamination: | 20ft bgs | |
Plume Size: | Plume Length: 120ft Plume Width: 130ft |
|
Average Depth to Groundwater: | 5ft |
Lithology and Subsurface Geology
Fine-grained sand, clay lense Depth: 0-4ft bgs 4ft thick Conductivity: 20.2ft/day Gradient: 0.0069ft/ft |
||
Peat & fine-grained sand Depth: 4-5ft bgs 1ft thick |
||
Fine-grained sand, clay lenses and peat Depth: 5-13ft bgs 8ft thick |
||
Fine-grained sand Depth: 13-36ft bgs 23ft thick |
||
Fine-grained sand & coquina Depth: 36-42ft bgs 6ft thick |
Pathways and DNAPL Presence
Groundwater Sediments Soil DNAPL Present |
Vapor Intrusion Pathway
Has the potential for vapor intrusion (VI) been evaluated? |
No |
|
Has a vapor mitigation system been installed? |
Yes | |
Type of Vapor Mitigation System(s): |
Soil Vapor Extraction |
Remediation Scenario
Cleanup
Goals: |
Groundwater (MCLs): PCE = 3 µg/l; TCE = 3 µg/l; cis 1,2-DCE = 70 µg/l; vinyl chloride = 1 µg/l Soils (Cleanup target leachability standard): PCE - 30 µg/kg |
Technologies
In Situ Soil Vapor Extraction |
Why the technology was selected: Date implemented: Final remediation design: Results to date: Cost to Design and Implement: |
|
Ex Situ Soil Removal |
Date implemented: Cost to Design and Implement: |
Costs
Cost
for Assessment: |
$62,622 | |
Cost
for Operation and Maintenance: |
$25,564 System Close Out & Site Rehabilitation: $15,939 | |
Total
Costs for Cleanup: |
$266,163 |
Lessons Learned
1. Since the contaminant mass was situated in the unsaturated zone and the shallow portion of the water table, it is believed that a substantial portion of the mass was remediated during the trenching and subsequent soil removal for installation of the horizontal SVE wells. |
Contacts
Aaron Cohen Florida Dept. of Environmental Protection Bureau of Waste Cleanup, MS 4500 2600 Blair Stone Road Tallahassee, Florida 32399 850-245-8974 Aaron.Cohen@dep.state.fl.us Contractor John McGovern, Contract Manager Foster Wheeler Environmental Corporation 759 South Federal Highway, Suite 100 Stuart, Florida 34994-3411 jmcgovern@fwenc.com |
Site Specific References
1. Contamination Assessment Report - 11/3/97 2. Remedial Action Plan - 7/2/99 3. Remedial Action Report - 2/14/2000 4. Operation & Maintenance Reports - 4/2000 & 10/2000 5. P&A Letter Report - 10/1/2001 |