Subsurface Containment and Monitoring Systems: Barriers and Beyond
(Overview Report)
March 1999
Prepared by
Leslie Pearlman
National Network of Environmental Management Studies Fellow
for
U.S. Environmental Protection Agency
Office of Solid Waste and Emergency Response
Technology Innovation Office
Washington, DC
http://clu-in.org
NOTICE
This document was prepared by a National Network of Environmental Management Studies grantee under a fellowship from the U.S. Environmental Protection Agency. This report was not subject to EPA peer review or technical review. The U.S. EPA makes no warranties, expressed or implied, including without limitation, warranties for completeness, accuracy, usefulness of the information, merchantability, or fitness for a particular purpose. Moreover, the listing of any technology, corporation, company, person, or facility in this report does not constitute endorsement, approval, or recommendation by the U.S. EPA.
FOREWORD
Within the past several years, the application of containment technologies to remediate contaminated subsurface zones has increased. EPA’s Technology Innovation Office (TIO) provided a grant through the National Network for Environmental Management Studies (NNEMS) to prepare a technology assessment report on subsurface barrier technologies that prevent the migration of contaminated material. This report was prepared by a graduate student from Duke University during the summer of 1998. It has been reproduced to help provide federal agencies, states, consulting engineering firms, private industries, and technology developers with information on the current status of this technology.
About the National Network for Environmental Management Studies (NNEMS)
NNEMS is a comprehensive fellowship program managed by the Environmental Education Division of EPA. The purpose of the NNEMS Program is to provide students with practical research opportunities and experiences.
Each participating headquarters or regional office develops and sponsors projects for student research. The projects are narrow in scope to allow the student to complete the research by working full-time during the summer or part-time during the school year. Research fellowships are available in Environmental Policy, Regulations, and Law; Environmental Management and Administration; Environmental Science; Public Relations and Communications; and Computer Programming and Development.
NNEMS fellows receive a stipend determined by the student’s level of education and the duration of the research project. Fellowships are offered to undergraduate and graduate students. Students must meet certain eligibility criteria.
About this Report
This report is intended to provide a basic summary and current status of subsurface barrier technologies for hazardous waste sites. It contains information gathered from a range of currently available sources, including project documents, reports, periodicals, Internet searches, and personal communication with involved parties. No attempts were made to independently confirm the resources used.
The report is available on the Internet at http://clu-in.org.
TABLE OF CONTENTS
Page
1.0 Introduction *1.1 Purpose and Scope *
1.2 Organization *
1.3 Overview of Subsurface Containment *
2.0 Established Technology *
2.1 Slurry Walls *
2.1.1 Soil-Based Slurry Walls *
2.1.2 Cement-Based Slurry Walls *
2.1.3 Soil-Cement-Bentonite Slurry Walls *
2.2 Sheet Pile Walls *
2.2.1 Waterloo BarrierTM *
3.0 Innovative Barrier Technology *
3.1 Frozen Barriers *
3.2 In Situ Soil Mixing *
3.2.1 Deep Soil Mixing (DSM) *
3.2.2 In Situ Enhanced Soil Mixing (ISESM) *
3.3 Composite Walls *
3.3.1 Geomembrane Composite Walls *
3.3.2 GSE GundWall® *
3.3.3 EnviroWall *
3.4 Grout Barriers (or Curtains) *
3.4.1 Jet Grouting *
3.4.1.1 Close-coupled Subsurface Barriers (Cement-Polymer Composite) *
3.4.1.2 Thin Diaphragm Barrier *
3.4.2 Permeation (or Pressure) Grouting *
3.4.2.1 Viscous Liquid Barrier *
3.4.3 Particulate and Chemical Grouting (Flowable) *
3.4.3.1 Montan Wax *
3.4.3.2 Glyoxal-Modified Sodium Silicate Grout *
3.4.3.3 Colloidal Silica *
3.4.3.4 PolySiloXane *
3.5 Vibrating Beam Cutoff Barrier *
3.6 Vitrification: GeoMelt *
3.7 Horizontal Barriers *
3.7.1 Horizontal Subsurface Barrier (HSSB) Technology (patent pending) *
3.7.2 Buried Waste Containment System *
3.8 Barrier Materials That Improve Performance *
3.8.1 Tires *
3.8.2 Microfibers *
4.0 Monitoring Wall Integrity *
4.1 Gas Tracers *
4.1.1 Perfluorocarbon Gas Tracers *
4.1.2 Science and Engineering Associates, Inc. (SEA) *
4.1.3 Comparison of PFTs and SEAtraceTM *
4.2 Electrical Resistance Tomography (ERT) *
4.3 Ground Penetrating Radar (GPR) *
4.4 Seismic/Acoustic Methods *
4.5 Electro-Acoustics (or Seismo-Electrics) *
4.6 Slurry Wall Monitoring (Germany) *
4.7 Monitoring of Slurry Walls in the United Kingdom *
Appendix A: Matrix for Evaluating Barrier CQA/CQC *
Appendix B: Groutability *
References *
FIGURES
Figure 1: Cross Section of a Typical Keyed-In Slurry Wall *
Figure 2: Waterloo BarrierTM Sealable Joint Steel Sheet Piling (WZ 75 profile) *
Figure 3: EnviroWall Barrier *
Figure 4: Cross-Section of the Close-Coupled Subsurface Barrier *
Figure 5: Thin Diaphragm Wall Emplacement *
Figure 6: Viscous Liquid Barrier Installation *
Figure 7: Typical HSSB Barrier *
Figure 8: SEAtraceTM Gas Tracer Monitoring System *
TABLES
Table 1: Comparison of Selected Cutoff Walls *
Table 2: Frozen Barrier: Physical Design Data for ORNL Project *
Table 3: Frozen Barrier: Cost of Installation and Maintenance for ORNL Project *
Table 4: General Assessment of Geomembranes as Vertical Walls *
Table 5: Installation Methods for Geomembrane Walls *
Table 6: Case Studies of Geomembrane Vertical Barriers *
Table 7: Estimated Installation Costs for EnviroWall *
Table B-1: Relationship Between Soil Permeability and Groutability *
Table B-2: Compatibility Between Soil Matrix and Grout *
This document is intended to provide information on the past, present, and future of subsurface barriers—vertical and horizontal—with an emphasis on the emerging and innovative vertical barrier technologies. It is not intended to be an inclusive report; it merely provides an overview of the existing work in the field of underground barriers.
Each section of this report provides the following information and format: (1) a brief description of the technology, (2) advantages, (3) disadvantage/limitations, (4) cost, (5) state of the technology, and (6) points of contact. For several technologies, there is such a wealth of knowledge available that additional references are provided.
1.3 Overview of Subsurface Containment
Subsurface contamination poses a continuing risk to human health and the environment. Liquid contaminants can migrate through the soil matrix and leach into groundwater, while solid and semi-solid pollutants may be transported and dispersed through the subsurface (GETF, 1996). Because cleanup technologies, when available for subsurface containment, can be costly and time consuming, it is necessary to examine other, possibly cheaper, ways to reduce the risk and protect human health and the environment at contaminated sites.
According to the 1996 Global Environment and Technology Foundation (GETF) market assessment, containment technology is "poised for significant, if not enormous growth." Underground containment barriers are an important method of limiting and/or eliminating the movement of contaminants through the subsurface. Subsurface barriers can maintain the volume of waste and reduce the potential for migration into the surrounding geologic media, or groundwater. In the past, containment has been used at sites where there was no other efficient and cost-effective option. However, subsurface barriers can be used in any number of situations where it is necessary to prevent the migration of contamination. Barriers are currently used for the containment of contaminated waste, as an interim step while final remediation alternatives are developed (or decided), and in coordination with treatment technologies. In many instances, subsurface barriers are able to effectively confine the contaminant for extended time periods and provide a cost-effective method of remediation.
There are many subsurface barrier technologies commercially available and others in various stages of development. The purpose and function of the containment system must be determined prior to designing and constructing the barrier. Site characterization is an essential part of choosing an appropriate barrier. Rumer et al. (1996) suggests some factors that should be considered when designing a subsurface barrier. First, it is important to establish the barrier geometry—alignment, depth, and thickness. Second, a stress-deformation analysis should be performed on the surrounding area in order to assess the potential impacts of barrier construction. Third, compatibility testing must be done to select the most effective barrier materials and when necessary, appropriate mixture combinations. Fourth, it is necessary to determine the most effective and feasible construction methods. Finally, construction quality assurance/quality control, along with monitoring, is a crucial component of subsurface barrier design.
Construction quality assurance (CQA) and construction quality control (CQC) are essential for the successful design, implementation, and performance of a subsurface barrier (Rumer et al., 1996, EPA 1998). The U.S. Environmental Protection Agency (EPA) defines quality control as "the contractor’s observations, sampling, measuring, and testing to establish conformance to plans and specifications" (1987). Quality assurance, as defined by the EPA, is conducted by or for the project engineer and provides further confirmation that the construction complies with the specifications of the design. Quality assurance is not mandated by the EPA (Rumer et al., 1996).
Different types of subsurface barriers have different CQC criteria, however there are two primary concerns. First, the installed barrier must have a hydraulic conductivity equal to or less than that specified in the design (Rumer et al., 1995). The second concern is barrier continuity, which is difficult to assess; the methods available have had varying degrees of success. Appendix A provides a brief overview of the standard industry practices for slurry walls. For additional information on CQA/CQC, see Evaluation of Subsurface Engineered Barriers at Waste Sites (EPA 542-R-98-005); Quality Assurance and Quality Control for Waste Containment Facilities (EPA 600-R-93-182); Construction Quality Management for Remedial Action and Remedial Design Waste Containment Systems (EPA 540-R-92-073); and Construction Quality Control and Post-Construction Performance Verification for the Gilson Road Hazardous Waste Site Cutoff Wall (EPA 600-2-87-065).
There is currently no method of guaranteeing the continuity of a subsurface barrier (Sullivan et al., 1998). Discontinuities may occur during grout application/installation and joint formation. Cracking due to curing, settling, and wet/dry cycling may occur over time. Proper emplacement of a subsurface barrier is critical to ensure overall effectiveness of the containment system. Once a barrier is installed, verification and monitoring are crucial. At this time, there is no uniform method of monitoring the emplacement, long-term performance, or integrity of the barrier. The Department of Energy (DOE) has acknowledged this problem and incorporated different monitoring techniques into containment projects.
Slurry walls are the most common type of subsurface wall and are considered baseline barrier technology (Heiser et al., 1997). "It is the expert consensus" that if properly designed and constructed, slurry walls can successfully contain waste at contaminated sites (Rumer et al., 1996). For over 45 years, these walls have been used in the construction industry to contain and direct water, and as a result, the requirements and practices for designing and installing a slurry wall are well established. Slurry walls have been used for pollution control since 1970, and the technology is accepted and regarded as an effective method of isolating hazardous waste and preventing the migration of pollutants (Gerber et al., 1994). Excavation under a slurry filled trench provides stability and prevents the trench from collapsing. Figure 1 is a diagrammatic representation of a typical slurry wall keyed into the subsurface.
Figure 1: Cross Section of a Typical Keyed-In Slurry Wall
Source: Adapted from the Department of Energy (DOE) website
There are different materials, and combinations of materials, that can be used to construct slurry cutoff walls including soil-bentonite, cement-bentonite, and plastic concrete. The backfill and composite typically contain a mixture of materials such as cement, bentonite, fly ash, ground-blasted furnace slag, and clay. Other types of cutoff walls include mix-in-place, grout, and composite walls. For a comparison of cutoff walls, see Table 1. Both organic and inorganic contaminants can have a negative impact on bentonite (in the wall and/or in the backfill). To help reduce this problem, additives can be used to alter the characteristics of the slurry wall. For example, additions of fly ash can potentially reduce the degradation of concrete by an alkali-silica reaction or sulfate attack.
Table 1: Comparison of Selected Cutoff Walls
Type |
Advantages |
---|---|
Cement-bentonite (CB) |
Strength, low compressibility Can be used on steep slopes with unstable soil Hydraulic conductivity around 10-6 cm/s |
Soil-bentonite (SB) |
Lower hydraulic conductivities than CB Cheaper than CB Hydraulic conductivity typically around 10-7 cm/s, but as low as 5.0 x 10-9 cm/s |
Soil-cement-bentonite (SCB) |
Similar to CB in strength and SB in hydraulic conductivity |
Plastic concrete (PC) |
Stiffer and stronger than cement-bentonite Preferred type of cutoff wall for deep walls (clam-shell or hydromill is used to excavate the trench) |
Mix-in-place |
Soil is not excavated |
Composite slurry |
Improved impermeability and resistance |
Grouting |
Can be used for barrier construction by injecting grout into holes or to seal fractures in impermeable layers |
Source: EPA, 1992
The application of soil-bentonite slurry walls involves excavation to the desired depth and eventual displacement of the slurry by a permanent backfill, which forms the hydraulic barrier. Varying the composition of the backfill can alter the properties of the barrier to obtain the desired strength or permeability. For example, the addition of plastic fines helps decrease the effect of contaminants on the barrier.
Advantages
Disadvantages
– Silica and aluminum in the bentonite and/or soil may dissolve in the presence of strong organic and inorganic acids (pH < 1) and bases (pH > 11) increasing the porosity of the barrier
– Inorganic salts and some neutral polar and nonpolar organic compounds result in the shrinkage of bentonite clay particles
Cost
The cost ranges from $5 – $7/ft2, not inclusive (Rumer et al., 1996). Cost varies depending on site conditions, type of slurry/backfill, depth, cleanup of spoils, and treatment of spoils.
Sources of Additional Information
1997 International Containment Technology Conference Proceedings. St. Petersburg, FL. February 9-12.
Rumer, R.R. and J.K. Mitchell, eds. 1996. Assessment of Barrier Containment Technologies A Comprehensive Treatment for Environmental Remedial Application. Product of the International Containment Technology Workshop. National Technical Information Service, PB96-180583.
Rumer, R.R. and M.E. Ryan, eds. 1995. Barrier Containment Technologies for Environmental Remediation Applications. Reproduced by the International Containment Technology Workshop. John Wiley and Sons, Inc., New York.
EPA. 1992. "Engineering Bulletin Slurry Walls." EPA 540-S-92-008.
2.1.2 Cement-Based Slurry Walls
A self-hardening slurry trench is a type of slurry wall that uses cement-bentonite as the permanent backfill. Cement-bentonite walls are advantageous when there is a lack of suitable soil for backfill, insufficient space available for mixing of backfill, a steep slope on site, or a very strong wall is required (shear strength) (Gerber et al., 1994). However, cement-bentonite walls tend to be more permeable than soil-bentonite walls. Permeabilities of cement-bentonite walls range from 10-5 – 10-6 cm/s, and the typical permeability required for site remediation is a minimum of 10-7 cm/s.
Self-hardening slurries typically consist of mixtures of Portland cement and bentonite clay. The bentonite is blended with water producing a hydrated slurry of approximately 6% bentonite by weight. Cement is added just prior to pumping the slurry into the trench. The cement content is usually 10 – 20% by weight (Mutch et al., 1997). Alternative self-hardening slurries incorporate ground-blast slag in with the cement to increase impermeabilities to 10-7– 10-8 cm/s. Additions of slag can also increase the chemical resistance and strength of the barrier. Typically, the mixing ratio of Portland cement to slag is 3:1 or 4:1 (Mutch et al., 1997).
Advantages
Disadvantages
Cost
Cost ranges from $10 – $20/vertical ft2 for a 2-ft wide barrier of less than 100 ft (Mutch et al., 1997)
Sources of Additional Information
1997 International Containment Technology Conference Proceedings. St. Petersburg, FL. February 9–12.
Rumer, R.R. and J.K. Mitchell, eds. 1996. Assessment of Barrier Containment Technologies A Comprehensive Treatment for Environmental Remedial Application. Product of the International Containment Technology Workshop. National Technical Information Service, PB96-180583.
Rumer, R.R. and M.E. Ryan, eds. 1995. Barrier Containment Technologies for Environmental Remediation Applications. Reproduced by the International Containment Technology Workshop. John Wiley and Sons, Inc., New York.
EPA. 1992. "Engineering Bulletin Slurry Walls." EPA/540/S-92-008.
2.1.3 Soil-Cement-Bentonite Slurry Walls
Soil-Cement-Bentonite (SCB) slurry walls are an adaptation of traditional soil- or cement-based walls. Fundamentally, the SCB wall is a soil-bentonite slurry wall with cement added to the backfill (less than 10%). The benefit of the SCB slurry wall is that it is similar to the cement-bentonite wall in strength and to the soil-bentonite wall in hydraulic conductivity (Rumer et al., 1996).
Sheet pile cutoff walls are constructed by driving vertical strips of steel, precast concrete, aluminum, or wood into the soil forming a subsurface barrier wall. The sheets are assembled before installation and driven or vibrated into the ground, a few feet at a time, to the desired depth. A continuous wall can be constructed by joining the sheets together. The joints between the sheet piles are vulnerable to leakage, and a number of patented techniques have evolved to seal them. In addition to different types of joints, a variety of sealants including grout, fly ash, and cement have been used to seal joints.
Advantages
Disadvantages
State of the Technology
Cost
The cost of a sheet pile barrier ranges from $15 – $40/ft2 depending on the depth, equipment used, type of joint, and type of sealant (Smyth et al., 1995).
Sources of Additional Information
International Containment Technology Conference Proceedings. 1997. St. Petersburg, FL. February 9–12.
Rumer, R.R. and J.K. Mitchell, eds. 1996. Assessment of Barrier Containment Technologies A Comprehensive Treatment for Environmental Remedial Application. Product of the International Containment Technology Workshop. Available through the National Technical Information Service, PB96-180583.
Design of Sheet Pile Walls: Engineering and Design. Technical Engineering and Design Guides as adapted from the U.S. Army Corps of Engineers, No. 15. ISBN: 0-7844-0135-7, Stock number 40135-7
The Waterloo BarrierTM is an adaptation of the sheet pile wall that addresses the problem of leaky joints. The Waterloo BarrierTM is specially designed to interlock sealable joints. See Figure 2 for a schematic of interlocking, sealable joints. Installation involves driving sheet piles into the ground, flushing the interlocking joint cavity to remove soil and debris, and injecting sealant into the joints. Depending on site conditions, the cavity may be sealed with a variety of materials including clay-based, cementitious, polymer, or mechanical sealants. Video inspection of the joint cavity prior to sealing ensures that the joint can be sealed. The Waterloo BarrierTM can achieve bulk hydraulic conductivities of less than 10-8 cm/s (Mutch et al., 1997). The barrier can easily be installed to depths of 75 ft and possibly deeper if piles are spliced together.
Figure 2: Waterloo BarrierTM Sealable Joint Steel Sheet Piling (WZ 75 profile)
Source: Oceta website
Advantages
Disadvantages
– Difficult to install in rocky or very dense soils
– Unable to key into rock
State of the Technology
3. In February 1997, the technology was installed at 19 sites.
Cost
Cost ranges from $15 – $25/ft2 including installation, materials, mobilization, and QA/QC reports (Robin Jowett, personal communication).
Points of Contact
Waterloo Barrier Inc.
Robin Jowett
P.O. Box 385, Rockwood, Ontario
N0B 2K0, Canada
Phone: 519/856-1352
Fax: 519/856-2503
http://www.waterloo-barrier.com
3.0 Innovative Barrier Technology
Frozen barrier walls, also called cryogenic barriers, are constructed by artificially freezing the soil-pore water. As the moisture freezes, the permeability decreases thereby forming an impermeable barrier. Once the wall is frozen, it remains impermeable and can prevent the migration of contaminants. When the barrier is no longer needed, the refrigeration system can be turned off, allowing the barrier to melt. In the past, this technology has been used for groundwater control and to strengthen walls at excavation sites.
The construction of a frozen barrier wall involves installing pipes called thermoprobes into the ground and circulating refrigerant (cryogenic) through them. As the refrigerant moves through the system, it removes heat from the soil and freezes the pore water. In arid regions, water can be injected into the soil to provide the moisture necessary to form the barrier or to repair the frozen wall. The thermoprobes can be placed in different configurations depending on the geologic media and the desired shape of the barrier. For example, if the pipes are installed at a 45E angle along the sides of the area to be contained and installed vertically on the ends, a V-shaped barrier will be formed providing complete containment.
The choice of refrigerant is site and contaminant specific. For example, if the site is polluted with a low freezing point contaminant like trichloroethylene (TCE), a refrigerant such as liquid nitrogen may be required. Other possible refrigerants include calcium chloride brine and carbon dioxide. Alternative refrigerants can have a dramatic effect on the overall cost due to different efficiencies in their refrigeration cycles (Erv Long, personal communication). In addition, friction or thermal resistance within the circulation systems can also reduce the efficiency.
Advantages
– Contaminated soil is not excavated
– No by-products (Arctic Foundations website)
– In situ repair by injecting water into the leakage area
Disadvantages
State of the Technology
The Arctic system, which is commercially available, uses an innovative thermoprobe consisting of the following components (Arctic Foundations, Ltd. website):
Table 2: Frozen Barrier: Physical Design Data for ORNL Project
Parameter |
Design Data |
---|---|
Initial Soil Temperature |
Approximately 66° F |
Length |
300 ft |
Depth |
30 ft |
Wall Thickness |
12 ft |
Frozen Volume |
108,000 ft3 |
Frozen Barrier Surface |
9,000 ft2 |
Contained Volume |
1,658,750 ft3 |
Number of Freeze Probes |
50 |
Freeze Probe Spacing |
6 ft |
Active Refrigerant |
R-404A |
Passive Refrigerant |
Carbon dioxide |
Evaporator Temperature |
-25° F (capable of -40° F) |
Source: Arctic Foundation, Inc.
Cost
There is a large difference in cost between the Cryocell® technology and the Arctic Foundation, Inc. technology (applied at ORNL). The main expense at ORNL was for drilling because the site was radiologically contaminated (Elizabeth Phillips, personal communication). For summary information of installation and maintenance costs of the frozen barrier wall installed at Oak Ridge, see Table 3.
The following cost estimates include waste disposal (Rumer et al., 1996):
Table 3: Frozen Barrier: Cost of Installation and Maintenance for ORNL Project
Cost Element |
Cost |
---|---|
Project installation ($) |
1,252,778 |
Power to freeze barrier ($) [67,000 kilo watt hour (KWH)] |
3,500 |
Site power ($ per KWH) |
0.052 |
Freezeback ($ per ft2) [Freezeback to 12 ft (61,416 KWH or 1.758 ft2/KWH)] |
139.20 |
Freezeback ($ per ft3 ) [Freezeback to 12 ft (61,416 KWH or 1.758 ft3/KWH)] |
11.60 |
Power only ($ per month) |
477 |
Total maintenance ($ per day) |
54.59 |
Maintenance ($ per ft2/day) |
0.0061 |
Maintenance ($ per ft3/day) |
0.0005 |
Total maintenance ($ per ft2/day) |
2.21 |
Total maintenance ($ per ft3/day) |
0.18 |
Source: Arctic Foundations Inc.; all other data from Arctic Foundations Inc., website
Points of Contact
RKK Ltd.
Cryocell® ground freezing technology (Patent No. 4,860,544)
8410 154th Ave., NE
Redmond, WA 98052
Phone: 425/861-6010
Fax: 425/558-5865
e-mail: rkk@cryocell.com
Arctic Foundations, Inc.
5621 Arctic Blvd.
Anchorage AK 99518-1667
Phone: 907/562-2741
Fax: 907/562-0153
e-mail: info@arcticfoundations.com
Layne Christensen Company
Tom Roberts, Environmental Drilling Manager
W229 N5005 DuPlainville Road
Pewaukee, WI 53072
Phone: 414/246-4646
Elizabeth Phillips, Principal Investigator
DOE-OR
Oak Ridge Operations Office
P.O. Box 2001, EW-923
Oak Ridge, TN 37830
Phone: 423/241-6172
Fax: 423/576-5333
e-mail: phillipsec@oro.doe.gov
Annette Gatchett, Associate Director for Technology
U.S. EPA
National Risk Management Research
Laboratory
26 W. Martin Luther King Dr.
Cincinnati, OH 45268
Phone: 513/569-7697
Fax: 513/569-7620
e-mail: gatchette.annette@ epa.gov
Steven A. Rock, Environmental Engineer
U.S. EPA
National Risk Management Research Laboratory
26 W. Martin Luther King Dr.
Cincinnati, OH 45268
Phone: 513/569-7149
e-mail: rock.steven@epa.gov
In situ soil mixing is a construction technology where the subsurface barrier is mixed-in-place. This method yields a smaller quantity of excavation spoils compared to external methods such as slurry walls.
Deep soil mixing (DSM), which was originally developed in Japan in the early 1960s, involves mixing an additive into the soil to produce a hard mass that acts as a barrier. The technology uses a special auger with a mixing shaft to simultaneously drill and inject the desired material, resulting in a column of soil and material. As the augers move through the earth, they loosen the soil, lift it into the mixing paddles, blend it with slurry, and inject it back out through the augers (Mutch et al., 1997). Possible slurry materials include bentonite, cement, lime, and additives (e.g., fly ash and slag that change the composition/durability of the material). DSM can be used to construct continuous walls by overlapping individual columns. Walls can be built up to 100 ft in depth.
Advantages
– Minimal disposal costs
– Reduced worker exposure
Disadvantages
– Difficult to verify continuity
– Care must be taken to ensure gaps are not present between panels
– Verticality is crucial
– Effective mixing to depths of 40 ft (DOE website), but commercial vendors claim they have reached depths of 100 ft
Cost
The cost varies depending on the soil characteristics and the grout material used. For example, soil-cement is more expensive than soil-bentonite (Rumer er al., 1996). The following are some cost estimates:
Points of Contact
Geo-Con, Inc.
4075 Monroeville Boulevard
Corporate One, Building II, Suite 400
Monroeville, PA 15146
Phone: 412/856-7700
Fax: 412/373-3357
Millgard Environmental Corporation
Phone: 313/261-9760
U.S. EPA’s Vendor Information System for Innovative Treatment Technologies (VISITT) 6.0 database has additional vendor information at http://www.epareachit.org.
3.2.2 In Situ Enhanced Soil Mixing (ISESM)
In situ enhanced soil mixing (ISESM) is a modification of the deep soil mixing technology (DSM). ISESM is advantageous because it can include a number of treatment technologies (DOE website). The following list illustrates the types of treatment technologies that can be used in conjunction with DSM technologies:
Advantages
Disadvantages
Cost
The estimated cost for the four technologies ranges from $120 – $175/yd3.
State of the Technology
1. In 1992, DOE conducted field demonstrations of the four types of ISESM technologies at the Portsmouth Gaseous Diffusion Plant near Piketown, OH.
2. In 1996, at the Kansas City Plant (a DOE project), technicians were able to mix at depths of 45 ft.
Points of Contact
Geo-Con, Inc.
4075 Monroeville Boulevard
Corporate One, Building II, Suite 400
Monroeville, PA 15146
Phone: 412/856-7700
Fax: 412/373-3357
Millgard Environmental Corporation
Phone: 313/261-9760
U.S. EPA’s Vendor Information System for Innovative Treatment Technologies (VISITT) 6.0 database has additional vendor information at http://www.epareachit.org.
In 1979, the first composite cutoff wall was installed in the Jordanian section of the Dead Sea (Rumer and Mitchell, 1996). A composite cutoff wall is formed by inserting a geomembrane liner into the trench of a slurry wall. The geomembrane adds reinforcement to the integrity of the wall and increases resistance to chemical attack. Construction techniques may vary, but installation generally involves mounting the geomembrane on an installation frame, lowering the frame plus geomembrane into the trench using weights, and then withdrawing the frame (Rumer and Ryan, 1995). Geomembrane panels are typically emplaced using the vibrating beam technology. See Section 3.5 for a description of this technology. The addition of the geomembrane can decrease the hydraulic conductivity up to five orders of magnitude (Jessberger, 1991). Geomembranes are particularly beneficial above the water table where soil-bentonite walls are susceptible to cracking due to wet/dry cycles. Geomembranes can be used with other types of walls (soil-cement, cement-bentonite, or soil-cement-bentonite) to provide added assurance against discontinuities. Application of this technology needs additional field-testing.
3.3.1 Geomembrane Composite Walls
Geomembranes were first used as vertical barriers in the early 1980s. They can be used alone or in conjunction with other containment systems. Although geomembranes are extremely impermeable when used in a composite wall, they can potentially provide an added level of protection. The permeability depends on the thickness of the geomembrane and the contaminant. While there are many kinds of geomembranes available, vertical walls are typically constructed of high density polyethylene (HDPE). Methods of installation include a trenching machine; vibrated insertion plate; slurry supported, segmented trench box; and vibrating beam (Rumer et al., 1996). There are different types of interlocks that can be used to connect the panels. The cost of HDPE ranges from $10 – $30/ft2 (Mutch et al., 1997).
Long-term durability of HDPE is not yet known. However, under normal conditions, HDPE is expected to have a lifetime exceeding 300 years (Belinda Burson, personal communication). The Drexal University Geosynthetic Research Institute is studying eight factors that influence HDPE degradation: oxidation, chemical attack, hydraulic effects, ultraviolet radiation, nuclear radiation, biological attack, stress effects, and temperature effects (Rumer and Mitchell, 1996). See Tables 4, 5, and 6.
Table 4: General Assessment of Geomembranes as Vertical Walls
Method Name |
Typical Cost |
Some Advantages |
Some Disadvantages |
|
---|---|---|---|---|
$/ft2 |
$/m2 |
|||
Trenching machine |
2-5 |
20-50 |
No seams Rapid installation No slurry |
Depth limitations Soil type limitations Trench stability necessary |
Vibration insertion plate |
3-7 |
30-70 |
Rapid installation Narrow trench No material spoils No slurry |
Soil type limitations Possible panel stressing Bottom key is a concern |
Slurry supported |
5-15 |
50-150 |
No stress on panels Conventional method Choice of backfill |
Requires slurry Buoyancy concerns Slow process |
Segmented trench box |
16-18 |
160-180 |
Can weld seams Visual inspection No stress on panels No slurry |
Depth limitations Soil type limitations Slow incremental process |
Vibrating beam |
18-25 |
180-250 |
Narrow trench No material spoils No stress on panels Usually CB slurry |
Requires slurry Slow incremental process Soil type limitations |
Source: Rumer et al., 1996
Table 5: Installation Methods for Geomembrane Walls
Method or Technique |
Geomembrane Configuration |
Trench Support |
Typical Trench Width mm (in.) |
Typical Trench Depth m (ft) |
Typical Backfill |
---|---|---|---|---|---|
Trenching machine |
Continuous |
None |
300-600 (12-24) |
1.5-4.5 (5-15) |
Sand or native soil |
Vibrated insertion plate |
Panels |
None |
100-150 (4-6) |
1.5-6.0 (5-20) |
Native soil |
Slurry supported |
Panels |
Slurry |
600-900 (24-36) |
No limit, except for trench stability |
SB, SC, CB, SCB, sand or native soil |
Segmented trench box |
Panels or continuous |
None |
900-1200 (36-48) |
3.0-9.0 (10-30) |
Sand or native soil |
Vibrating beam |
Panels |
Slurry |
150-220 (6-9) |
No limit |
SB, SC, CB, SCB slurry |
Source: Rumer et al., 1996
Table 6: Case Studies of Geomembrane Vertical Barriers
Reference |
Type of Contained Waste |
Type of Installation |
Depth of Wall |
Length of Wall |
Type of Interlock |
Backfill |
||
---|---|---|---|---|---|---|---|---|
m |
ft |
km |
mi |
|||||
Burnette & Schmednecht |
Hazardous |
Vibrating beam |
10 |
35 |
0.3 |
0.2 |
Curtain Wall InterlockTM |
Clay/cement slurry |
Bliss & Burnette |
Earth dam cutoff |
Slurry supported |
15 |
50 |
20 |
12.5 |
Curtain Wall InterlockTM |
Sand |
Burnette & Pierce |
Petroleum |
Slurry supported |
4.5 |
15 |
0.4 |
0.2 |
Curtain Wall InterlockTM |
Sand |
Burnette & Pierce |
Hazardous |
Slurry supported |
14 |
45 |
0.5 |
0.3 |
Curtain Wall InterlockTM |
Sand |
Scuero, et al. |
Earth dam cutoff |
Slurry supported |
9 |
30 |
0.1 |
0.1 |
GeolockTM |
CB slurry |
Michalangeli |
Ash & MSW |
Slurry supported |
Various |
Various |
Grouted |
CB slurry |
||
Hansen & Crotty |
Contaminated drilling waste |
Trenching machine |
3 |
10 |
34 |
21 |
Welding |
Natural soil |
Source: Rumer et al., 1996
The GundWall® system uses sheets of 2 mm high density polyethylene (HDPE) to form barrier walls. The method of installation depends on the depth and length of the wall, contaminant, and soil type. Groundwater Control, Inc. (GCI) uses a patented interlock developed in Holland and a unique hydrophilic rubber cord to seal the interlocks. The interlocks are joined to the HDPE by fusion welding and then sealed with a chloroprene-based hydrophilic seal (Burson et al., 1997). The seal is 8 mm in diameter and expands, up to eight times its original volume, when exposed to water (Belinda Burson, personal communication). The seals are monitored for continuity during panel installation. Because the interlock is designed to be stronger than the geomembrane, the HDPE will stretch under stress (Burson et al., 1997). The barrier can be keyed into clay, but if the confining layer is rock, keying in will fracture rock and cause leakage. For additional protection, jet grouting can be used to prevent leakage between the geomembrane and the bedrock.
The two primary methods of installation are a trencher system and vibratory pile-driving (trenchless) method. GCI has developed a unique deep trencher that is simultaneously able to cut a narrow trench, support the sidewalls, and install HDPE walls. As the trencher moves through the soil, it cuts a narrow trench (ranging from 16 – 22 inches in diameter) and places HDPE in the trench. The special interlock system allows an HDPE wall to be placed using vibratory installation, with conventional vibratory pile-driving equipment.
Disadvantages
Cost
Cost varies depending on soil characteristics, depth and length of wall, and drilling technique. The trencher method costs $9 – $15/ft2 and the vibratory method costs $12 – $25/ft2 (Belinda Burson, personal communication).
State of the Technology
Points of Contact
Groundwater Control, Inc.
Belinda Burson, Vice President of Vertical Barriers Division
Jeff Haluch, Executive Vice President
11511 Phillips Highway
Jacksonville, FL 32256
Phone: 904/886-3700 or 800/843-6133
Fax: 904/886-377
e-mail: BBGCI@aol.com
GSE Lining Technologies, Inc., HDPE supplier
19103 Gundle Rd.
Houston, TX 77073
Phone: 281/443-8564
Fax: 281/875-6010
The EnviroWall barrier technology combines six patented techniques for emplacing subsurface vertical barriers of high-density polyethylene (HDPE). See Figure 3 for a schematic diagram of the EnviroWall. The barrier may be installed for containment purposes, as a groundwater recovery system, or in conjunction with a treatment system for remediation. The system is flexible and can be altered to meet many needs. For example with a treatment wall, contaminated groundwater can be collected upgradient of a HDPE barrier, and treated groundwater can be discharged downgradient of the barrier.
The installation system is a patented process involving trench and guide-box construction. Interconnected guide boxes (8 ft long) are temporarily placed in the trench to provide support and to permit the panels to be emplaced at the desired depth. Stacking guide boxes allows deeper walls to be installed (Buddy Breaux, personal communication). Spools of HDPE geomembrane are inserted into the guide box and unrolled along the length of the barrier forming panels up to 240 ft in length (EnviroWall brochure). Insert-beams, located inside the guide boxes, help hold the geomembrane in a vertical position. Geomembranes are sealed together using a specially patented interlocking system. The joints have an elastomeric seal with a double mechanism on the interlocking joints (Buddy Breaux, personal communication). Joining the interlocks "creates a virtually impervious barrier" (Dunn, 1994). A downhole video camera is used to visually inspect the integrity of the geomembrane and interlock system before backfill is added.
Source: EnviroWall Ltd. Information
A Bentonite "Hole PlugTM" is poured into the guide box forming a seal along the bottom of the barrier. Backfill is added to the top of the guide box before the guide box is removed. The backfill material is site and contaminant specific and can be used to control water flow or act as a treatment wall. For long-term monitoring, it is easy to install multi-level monitoring wells, pressure transducers, and in situ monitoring instruments such as pH sensors, flow meters, and vadose zone lysimeters on both sides of the barrier wall.
Advantages
Disadvantages
Cost
See Table 7 for estimated costs for the funnel and pass through gate system (inclusive).
Table 7: Estimated Installation Costs for EnviroWall
Length of Wingwalls |
||
---|---|---|
Depth (ft) |
100 ft |
500 ft |
8 |
$47426.00 |
$103,178.00 |
11 |
$59,269.20 |
$132,862.00 |
14 |
$71,670.00 |
$165,333.20 |
17 |
$85,185.60 |
$203,380.00 |
20 |
$100,559.60 |
$250,718.40 |
23 |
$116,863.20 |
$302,703.20 |
26 |
$138,184.00 |
$379,776.00 |
29 |
$155,905.20 |
$456,849.20 |
32 |
$180,826.00 |
$533,922.00 |
35 |
$202,147.20 |
$610,995.20 |
Source: EnviroWall Ltd.
State of the Technology
Points of Contact
Buddy Breaux (patent holder)
EnviroWall Ltd.
2217 RidgeLake Drive
Metairie, LA 70001
Phone: 504/398-0501
Fax: 504/328-3997
Robert McLeod
Hydrology and Water Resources Engineering Consultants
130 Timbercrest Drive
Oak Ridge, TN 37830
Phone: 423/482-9385
3.4 Grout Barriers (or Curtains)
Jet grouting was developed in the early 1970s in Japan and was introduced into Europe in the late 1970s and into the United States in the 1980s (Dwyer, 1998). It was developed for use on conventional civil engineering problems such as excavation support. Methods of jet grouting are based on a water cutting technology that includes a single-rod system (injecting grout alone), a double-rod system (injecting grout and air) or a triple-rod system (injecting grout, air, and water) (Rumer et al., 1995, Mutch et al., 1997). Typically, a Portland cement grout or cement-bentonite grout is used. Larger diameter columns can be constructed with the triple-rod system.
Jet grouting involves injecting a grout mixture at very high pressures (up to 5,000 – 6,000 pounds per square inch) and velocities (as great as 800 – 1,000 ft/s) into the pore spaces of the soil or rock. The jetted grout cuts, replaces, and mixes the soil with cementing material to form a column. Rotation of the drill rod, as it is being removed, will form a column. A panel is formed by leaving the drill rod in place (EPA, 1998). The soil structure is destroyed as grout and soil are mixed, forming a homogeneous mass. Jet grouting can be used in soil types ranging from gravel to clay, but the soil type can alter the diameter of the grout column. Soil properties also are related to the efficiency. For instance, jet grouting in clay is less efficient than in sand (Heiser et al., 1997).
Advantages
– DTH percussion hammer
– Multi-nozzle grout injection unit increases the efficiency of injection
Disadvantages* (Heiser et al., 1997, Mutch et al., 1997)
* A solution to many of the disadvantages is to inject two overlapping rows of barrier material.
Cost
Cost ranges from $15 – $30/vertical ft2 (Mutch et al., 1997).
3.4.1.1 Close-coupled Subsurface Barriers (Cement-Polymer Composite)
A close-coupled barrier combines a thin (inner) lining of polymer grout with a conventional, low-cost cement-grout containment barrier. The resultant barrier is a cement-polymer composite deriving economic benefits from the cement, and performance benefits from the polymer (Heiser et al., 1997). See Figure 4 for a diagrammatic representation of a close-coupled subsurface barrier. Close-coupled subsurface barriers are installed using jet grouting with a dual fluid injection system. The dual pump system was devised to avoid problems with rapid gel times. The system allows split streams of two different grouting media to be jetted simultaneously. Polymerization occurs when the two parts are mixed. The grouts mix together only after leaving the drill equipment. This avoids clogging the drill system. Mixing occurs normally as a result of the high pressure jetting. Dual fluid injection is preferred when using thermosetting polymers that gel after about 30 minutes (Heiser et al., 1997).
Figure 4: Cross-Section of the Close-Coupled Subsurface Barrier
Source: Adapted from Heiser et al., 1997
Advantages
– Adequate for the containment of the majority of waste forms
– Readily available
– Easy to work with
– Low cost
– Compatible with virtually any waste form (SCFA, 1996)
Disadvantages
Cost
The cost of the barrier grout increases with performance and durability (Heiser et al., 1997). The chosen grout is site and contaminant specific. The estimated cost for a standard DOE site that is 2 acres and 20 ft deep is $24/m3 (Heiser et al., 1997 and Dwyer, personal communication).
Results from the Hanford and BNL projects:
Points of Contact
John Heiser
Environmental and Waste Technology Center
Brookhaven National Laboratory
P.O. Box 5000, BLDG 830
34 N Railroad
Upton, NY 11973-5000
Phone: 516/344-4405
Fax: 516/344-4486
e-mail: heiser@bnl.gov
Brian Dwyer
Sandia National Laboratories
MS 0719
Albuquerque, NM 87185-0719
Phone: 505/845-9894
Fax: 505/844-0543
e-mail: bdwyer@sandia.gov
3.4.1.2 Thin Diaphragm Barrier
The thin diaphragm barrier is emplaced using high pressure jet grouting. While this grouting technique has been used for years in civil engineering applications, it has only recently been considered for environmental/remediation related purposes (SRT, 1997). Installation involves drilling a horizontal or angled borehole, inserting a rod-string to the desired depth, and removing the string at a constant speed. As the string is removed, grout material is injected through the nozzle at a pressure of approximately 5,700 pounds per square inch. To facilitate the penetration of grout through the subsurface, a cone of air surrounds the grout as it is injected through the nozzle (Carey Johnston, personal communication). The resultant thin diaphragm barrier is composed of a mixture of grout and parent material. Excess soil and fluid, forced to the surface surrounding the drill rod, are contained in a "spoils box." The drill consists of two injection nozzles positioned 180E apart. This configuration enables the formation of thin panels approximating 4 – 8 inches thick and 10 ft wide. See Figure 5 for diagrammatic representation of the emplacement of a thin diaphragm barrier.
Advantages
– No excavation required
– Grout is injected through a borehole into the ground to form the barrier
– Expected to significantly lower risks (DOE, Technology Overview)
Figure 5: Thin Diaphragm Wall Emplacement
Source: Adapted from Carey Johnston, U.S. EPA, Radiation Protection Division
Disadvantages
Cost
An estimated cost of installing a thin diaphragm barrier, using high-pressure jet grouting, is $10 – $15/ft2 (Rumer and Mitchell, 1996). This estimate does not include the costs of waste disposal or materials.
State of the Technology
The panels were installed at an angle in order to provide reinforcement at the overlapping areas. The verification methods included hydraulic testing (Westinghouse Savannah River Company), gas and groundwater tracers (Sandia National Laboratory and Science and Engineering Associates, Inc.), and geophysical testing (MSE-TA, Lawrence Livermore National Laboratory, Lawrence Berkeley National Laboratory). Results are expected by 1999.
Points of Contact
Carey Johnston
U.S. EPA, Office of Air and Radiation (6602J)
401 M Street, S.W.
Washington, DC 20460
Phone: 202/564-9341
e-mail: johnston.carey@epamail.epa.gov
3.4.2 Permeation (or Pressure) Grouting
Permeation grouting has been used extensively in the United States and overseas in the civil engineering, mining, and geotechnical fields (Mutch et al., 1997, Dwyer, 1994). This technique involves the injection of a low-viscosity grout into the soil at low pressure. The grout fills the soil voids to achieve low permeabilities without significantly changing the structure or volume of the soil. To avoid hydrofracture, the grout pressure should not exceed the soil fracture pressure (Rumer et al., 1995).
The first step of the process involves grouting the sleeve pipe annulus with a brittle grout material (weak) prior to injection with the selected grout(s). Once hardened, the "real" grout is injected at a pressure that will fracture the annulus grout thereby directing grout radially into the formation at the designated interval (Dwyer, 1994). Injection pressure is lowered as pressure decreases from fracturing of the annulus grout to ensure permeation and avoid hydrofracturing of the formation (Dwyer, 1994).
Permeation grouting is a feasible method for emplacing a low permeability subsurface barrier in semi-arid unconsolidated alluvial soils common in the southwest United States. The degree of grout permeation is a function of the grout viscosity, grout particle size, and the particle size distribution. These characteristics are directly correlated with the soil hydraulic conductivity. Understanding the relationship between these parameters is essential for predicting grout flow characteristics (Dwyer, 1994).
A variety of materials can be used in permeation grouting, and it is essential to select a grout that is compatible with the soil matrix. Particulate grouts are applicable when the soil permeability is greater than 10-1 cm/s (Karol, 1990). Chemical grouts can be used with soil permeabilities greater than 10-3 cm/s (Karol, 1990). For further information on groutability and compatibility, see Appendix B.
There are currently two main methods of permeation grouting: point injection and sleeve pipe injection (tube-a’-manchette). In the point injection method, the casing is driven to full depth and grout is injected as the casing is withdrawn (Rumer et al., 1995). Overlapping injection holes can be used to form a continuous barrier. The tube-a’-manchette method involves grouting a sleeve pipe in the grout hole and injecting grout through holes in the pipe (Rumer et al., 1995). The holes are covered and placed at 1 ft intervals along the pipe. The grout is injected under pressure into the soil. The advantage of the tube-a’-manchette method is that different grouts can be injected into different holes, and grout can be re-injected if there is a problem.
Advantages (Mutch et al., 1997 and Dwyer, 1994)
Disadvantages
Cost
The cost is often dominated by directional drilling. Cost estimates for directional drilling are
$7 – $17/ft2 (Rumer and Mitchell, 1996). These estimates do not include grouting materials, waste disposal, surface support equipment, and other contingencies.
State of the Technology
Verification
Phase I
(BNL microfine cementitious grout)Phase II
(montan wax and sodium silicate)Results
The interconnection between soil pore spaces will determine groutability (Dwyer, 1994). Permeation grouting can be used with gravels and sands but is only marginally successful for silts and clays (Dwyer, 1994). Microfine cementitious grout can be used to grout high hydraulic conductivity soils. The penetration radius depends on soil heterogeneity, grout viscosity, and injection pressure (Dwyer, 1994). Non-uniform grout flow was attributed to soil characteristics because viscosity and injection pressures were held constant. The grout tended to follow the path of least resistance and flowed primarily along the horizontal plane.
Results of Excavation (Dwyer, 1994)
Conclusions (Dwyer, 1994)
3.4.2.1 Viscous Liquid Barrier
Viscous liquid barrier (VLB) technology uses injectable, environmentally benign materials to form a containment barrier. Low viscosity liquids are injected using permeation grouting through multiple boreholes in the subsurface. After injection, the liquids gel, forming an impermeable barrier that is biologically and chemically inert, unaffected by filtration, and environmentally safe. See Figure 6 for a diagram of a VLB. VLBs have multiple applications including encapsulation (permanent immobilization of contamination) and creation of an impermeable container that surrounds and isolates the contaminants. They also have the ability to seal off permeable aquifer zones to provide containment in coordination with treatment (Moridis et al., August 1996). The field tests have had mixed success in being able to attain the desired hydraulic conductivities (see state of the technology section).
In collaboration with the manufacturers, special formulations of Colloidal Silica (CS) and PolySiloXane (PSX) were designed specifically for the VLB (Moridis et al., August 1996). See Section 3.4.3.1 for more information on CS and PSX. The new formula CS was designed to resist soil chemistry effects, and the new PSX has a lower initial viscosity (Moridis et al., September 1998). Both of these materials can be injected using standard/available equipment.
It is necessary to match the injection fluid to the waste and to soil characteristics. The geologic matrix appears to be critical to the application and success of this technology (Van Price, personal communication). Soil permeability affects the gel time (Moridis et al., September 1996). In high permeability soils, it is advantageous for the grout to gel quickly so it remains in the desired region. In contrast, in low permeability soils, it is beneficial for the grout to gel slowly so it will have time to invade the desired region prior to setting. Permeability is also important for determining injection well spacing.
Figure 6: Viscous Liquid Barrier Installation
Source: Adapted from Moridis et al., 1996
Advantages
– Permeability depends on grout permeability and saturation in the pore space
– Contamination is not disturbed
– Cost is reduced because there are no spoils to treat
– Minimum risk of human exposure
Disadvantages
Cost
At Brookhaven National Laboratory (BNL), the cost for the VLB demonstration was $593,000 (MSE-TA, 1998), whereas, the model predicted the cost would be $550,000, a value that is within 10% of the actual demonstration costs. The VLB proved to be a cost-effective alternative compared to excavation and disposal. Based on identical site size and conditions, it was estimated that excavation and disposal would cost $2,122,000. Construction of a slurry wall under the same conditions would cost approximately $91,000 (MSE-TA, 1998).
The cost data for the BNL project included equipment, grout materials, labor, and emplacement. Site-specific characteristics, such as project management, permitting, engineering support, engineering design, and site characterization were not incorporated into the analysis (MSE-TA, 1998). Cost will vary depending on the grouting method, drilling method, depth of drilling, and grouting materials. The verification cost is $3/ft2 of barrier and monitoring is $2/ft2 (MSE-TA, 1998).
State of the Technology
The VLB technology was developed at the Lawrence Berkeley National Laboratory (LBNL). Over the last eight years, DOE has invested $12 million in the design, testing, and implementation of this technology (Scott McMullin, personal communication). The work was supported originally by a CERCLA action at the Savannah River Site (SRS) Retention Basin 281-3. A different technology was chosen for the SRS, but the potential exists for using VLB at other DOE sites (Wes Germany, personal communication).
CS Performance Characteristics:
PSX Performance Characteristics:
Andrea Hart, Project Manager
MSE-TA, Inc.
P.O. Box 4078
Butte, MT 59702
Phone: 406/494-7410
e-mail: ahart@in-tch.com
George Moridis, Principal Investigator
Lawrence Berkeley National Laboratory
Phone: 510/486-4746
Fax: 510/486-5686
e-mail: GJMoridis@lbl.gov
John Apps, Principal Investigator
Lawrence Berkeley National Laboratory
Phone: 510/486-5193
Fax: 510/486-5686
e-mail: JAApps@lbl.gov
Skip Chamberlain, DOE EM-50 Program Manager
19901 Germantown Road
MS 1135CL, Cloverleaf Building
Germantown, MD 20874
Phone: 301/903-7248
Fax: 301/903-1530
e-mail: grover.chamberlain@em.doe.gov
3.4.3 Particulate and Chemical Grouting (Flowable)
Grout barriers are constructed using particulate or chemical grouts or a combination of both. The most common grouts are particulate grouts including slurry mixtures of cement, bentonite, and water. Particulate grouts tend to be more viscous and better adapted to large pore spaces where they can spread through the pores. Chemical grouts typically contain a chemical base, a catalyst, and a solvent such as water (EPA, 1998). Examples of chemical grouts include montan wax, sodium silicate, acrylate, urethane, or Ludox. Ludox is a colloidal silica gel developed by DuPont. The density and viscosity of Ludox are similar to water and the gel time can be controlled from a few hours to thousands of hours. Laboratory results show a decrease in permeability of four orders of magnitude (Mutch et al., 1997).
The concept of using montan wax for containment was developed in Germany in 1985 by a company called Vereinigte Mitteldeutsche Braunkohlenwerke AG (MIBRAG). The injected material is a combination of melted wax, surfactant, bentonite, and water. Melted wax is injected into water at a temperature of 95° – 98° C, and then a small amount of surfactant is added to the emulsion (Voss et al., 1993). Additions of sodium bentonite clay break the emulsion, causing the particles of wax to aggregate. In the subsurface, the particles continue to bind to one another, thus, filling voids and forming an impermeable barrier. The temperature of the wax and water, as well as the amount of bentonite, can be altered depending on the permeability of the soil.
Montan wax was first mined in 1921. The largest know deposits of montan wax are in the coal fields of former East Germany. The mining process involves extraction of the wax from coal. Montan wax, used to form subsurface barriers, is typically mixed with bentonite. The addition of sodium bentonite serves to bind the surfactant causing the wax particles to aggregate.
Properties of Montan Wax (Voss et al., 1994):
Advantages
Disadvantages
– Montan wax, mined in Germany, is imported and soil in the United States by
Strohmeyer and Arpe, Inc.
– Northern California
The following are some potential applications (Kretzschmer, 1997):
State of the Technology
FlowWaste GMBH
Ingo Sass
Entsorgungsmanagement
Am Hardtwald 1
76275 Ettlingen, Germany
Phone: +49-7243/549744 or
+49-7243/549700
Fax: +49-7243/549799
FlowTex®
Burkard Lenze
Chausseestraße 1
D-06317 Amsdorf
Post Röblingen
Germany
Phone: +49-3460/140163
Fax: +49-3460/140159
3.4.3.2 Glyoxal-Modified Sodium Silicate Grout
The Societe Francaise Hoechst in France developed glyoxal-modified sodium silicate (sold under the trade name of KlebogelTM). Sodium silicate is a grout consisting of water, KlebolinkTM S, Klebolink H1, and Klebolink K (Voss et al., 1994). Changing the proportions of these compounds can alter the hardening time and viscosity. The set/gel time is controlled by the purity of the material. Sodium silicate has been used extensively in the United States and Europe as a soil strengthener in unconsolidated soils (Voss et al., 1994).
Advantages
Disadvantages
Cost
The cost of the grout material is a function of the desired set time. A fast setting mix (up to 2 hours) does not include silica sol and costs about $1/gallon. A slow setting mix (up to 2 days) includes silica sol and costs about $2/gallon (Roberds et al., unpublished).
State of the Technology
1. In 1993 – 1994, DOE tested sodium silicate. No work seems to have been done since that time.
PQ Corporation, Valley Forge, PA, developed a Colloidal Silica (CS) formulation called Nyacol DP5110. The CS contains an isomorphic substitution of silicon by aluminum on the surface. For applications of CS, see Section 3.4.2.1 Viscous Liquid Barrier.
Advantages
– At Los Banos, CaCl2 electrolyte solution used
– Gel time is temperature dependent
Disadvantages
The PolySiloXane (PSX) tested was called 2-7154-PSX-10 and was developed by Dow Corning in Midland, MI. For applications of PSX, see Section 3.4.2.1 Viscous Liquid Barrier.
Advantages
3.5 Vibrating Beam Cutoff Barrier
The vibrating beam is a grouting method suitable for shallow soils. A vibratory pile driver is used to drive a modified H-beam into the subsurface. The pile has injection nozzles at the tip. As the beam is withdrawn, grout is injected through the nozzles into the void (Rumer et al., 1995). Cement-bentonite grouts are used most often. A continuous barrier can be formed by successively overlapping beam penetrations.
Advantages
Disadvantages
In 1980, Batelle Memorial Institute developed the process of in situ vitrification for DOE, and in 1983, Geosafe Corporation sublicensed the technology. In situ vitrification technology applies electricity between four graphite electrodes to generate temperatures (1,600° – 2,000° C), high enough to melt the soil and contaminants in the soil. Contaminants may be destroyed, removed, or immobilized (Campbell et al., 1996). This process incorporates inorganic contaminants (e.g., heavy metals and radionucleotides) into the vitrified glass and destroys most organic pollutants through pyrolysis (heat affected chemical bond breaking) (EPA ORD website, in situ vitrification). The resulting product is glass, which is nonhazardous, chemically stable, and immobile. The organic by-products escape from the soil as gases. The temperature necessary to melt the soil depends on the alkali metal oxide content of the soil (EPA ORD website). In order for this technology to work, the soil matrix must contain at least 1.4% sodium and potassium oxides by weight. Most soils contain this quantity (EPA ORD website).
GeoMelt is one type of vitrification, developed within the last year by Geosafe Corporation (Jim Hanson, personal communication). Planar melting is a type of vitrification involving vertical melting and the formation of vertical planes.
The vitrified product is five to ten times stronger than regular concrete (GeoMelt fact sheet) and is not affected by wet/dry or freeze/thaw cycles. Additionally, organics are removed and the expected geologic lifespan is thousands to millions of years.
Advantages*
*These are advantages of vitrification in general and are not specific to containment barriers.
Disadvantages*
*These are disadvantages of vitrification in general and are not specific to containment barriers.
State of the Technology
Points of Contact
Geosafe Corporation
2952 George Washington Way
Richland, WA 99352
Phone: 509/375-0710
3.7 Horizontal Barriers
3.7.1 Horizontal Subsurface Barrier (HSSB) Technology (patent pending)
The horizontal subsurface barrier (HSSB) technology involves fracturing the soil matrix by "creating stress points" over a broad area (Muhlbaier et al., 1997). The soil tends to preferentially fracture along the horizontal plane. HSSB uses air injected into the boreholes at increasing air pressures to cause the soil to fracture. After soil fracture formation, fluid is injected along the fracture. At the Savannah River Site, Bingham fluid was injected along the plane of the fracture. See Figure 7 for schematic diagram of HSSB.
Figure 7: Typical HSSB Barrier
Source: Adapted from RCS
Advantages
Disadvantages
The following additional factors should be considered when applying this technology:
State of Technology
Points of Contact
Dave Muhlbaier
Soil Remediation Barriers Company
5 Whitemarsh Drive
Aiken, SC 29803
Phone: 803/648-8246
e-mail: drmuhlbaier@csranet.com
3.7.2 Buried Waste Containment System
RAHCO International, Inc. developed a horizontal buried waste containment system for Idaho National Engineering and Environmental Laboratory (INEEL). The technology involves constructing a horizontal slot beneath the existing waste, injecting cementitious material into the opening, and monitoring to ensure successful emplacement of the barrier. Tests performed in 1997 proved the technology to be feasible and very successful (Ann Marie Smith, personal communication). Lockheed Martin Idaho Technologies Company (LMITCO) performed the initial site surveys, barrier studies, and sensor evaluations for the test.
The construction of the buried waste containment system utilizes specialized cast-in-place barrier placement machines (BPM) and conventional trenching equipment. The BPM excavates a trench on the sides and underneath the waste. As the trenches are being excavated, the machine injects grout into the trenches (Molony et al., 1998). The soil is excavated by minidiscs and used to backfill the trench after the grout has been injected. The BPM installs both the impermeable horizontal barrier and long-term monitoring equipment. A grid of fiber optic sensors and sensor tubes are installed with the grout. The sensors are embedded in the barrier trenches for long-term monitoring. In addition, the BPM contains a barrier void detection system consisting of a series of pressure sensors along the injection head (Molony et al., 1998). The sensors are capable of detecting a drop in pressure caused by a void in the barrier. When a void is detected, the system will automatically alter the flow of grout.
Advantages
Disadvantages
State of the Technology
Points of Contact
RAHCO International, Inc.
P.O. Box 7400
Spokane, WA 99207
Phone: 509/467-0770
Fax: 509/466-0212
3.8 Barrier Materials That Improve Performance
Scrap tire chips were first added to slurry walls as a method of decreasing the mobility of VOCs through engineered containment systems. Shredded tires were found to significantly improve the ability of slurry walls to contain VOCs. Park et al. (1996) has shown that adding ground tires to the soil-bentonite slurry backfill can reduce the hydraulic conductivity of the cutoff wall. The shredded tires adsorb (sorb) VOCs, such as toluene, methylene chloride, trichloroethylene (TCE), and m-xylene from the solution. Park et al. (1996) chose to test these organics because they are commonly present at waste disposal sites.
Tire pieces ranging from 1.3 – 2.5 cm effectively sorbed the VOCs. The necessary thickness of shredded tires depends on the amount of organic compounds to be removed. Park et al. (1996) found that compounds requiring larger quantities of tires for sorption were also more biodegradable, so a thickness greater than 30 cm would rarely be necessary. Differences in sorbance capacity of the ground tires depended on the characteristics of the polymers in the tires (Kim et al., 1997), and sorption was not temperature or pH dependent.
Advantages
Disadvantages
Cost
The cost of adding tires to a slurry wall is minimal and should not significantly increase the price of the wall.
State of the Technology
Points of Contact
Jae (Jim) Park, Associate Professor of Environmental Engineering
Department of Civil and Environmental Engineering
University of Wisconsin-Madison
3230 Engineering Hall
1415 Engineering Drive
Madison, WI 53706
Phone: 608/262-7247
Fax: 608/262-5199
e-mail: park@engr.wisc.edu
Cement barriers risk cracking, thereby diminishing the strength of the containment system and increasing the potential for leakage. Cracks pose a special problem when the barrier is exposed to repeated wet-dry cycles (Allan et al., 1995). Polypropylene fibers have been found to "improve toughness, reduce cracking from plastic shrinkage, and decrease crack width and transfer stress across cracks" (Bentur, 1989 in Allan et al., 1995). The potential benefit gained by adding fibrillated polypropylene fibers is that the fibers can reduce microcrack width in shrink-swell soils. While fibers do not stop the formation of cracks, they can reduce the extent of cracking by decreasing crack width and growth, thereby improving the overall performance of the grout (Allan et al., 1995). The addition of fibers increases the strength of the barrier, but it does not change the permeability (Rumer and Mitchell, 1996). The addition of fibers is not always beneficial (Allan et al., 1995).
State of the Technology
1. Brookhaven National Laboratory was working on the addition of microfilaments until several years ago, but currently, there appears to be no research in this area, even though Rumer and Mitchell (1996) have mentioned that microfibers provide added strength.
4.1.1 Perfluorocarbon Gas Tracers
Perfluorocarbon Gas Tracers (PFTs/PFCs) are involved in a geophysical technique that can be used in the vadose zone to determine the physical properties of a barrier. However, existing subsurface geophysical techniques are unable to detect small defects (less than an inch) in a barrier at depths greater than 100 ft. PFT technology requires the following equipment: tracer gases, injection equipment, samplers, and analyzers. Tracer technology is based on the rate of migration of a tracer from the point of injection to a collection well (Sullivan et al., 1998). Gas tracers are injected on the inside of the barrier, and concentrations of the gas are measured in geoprobe monitoring wells outside of the barrier. A capillary adsorbent tracer sampler (CATS) is usually used to measure the monitoring well concentrations of PFTs.
The concentration of PFTs in the external monitoring wells is used to determine if there is a breach in the barrier. If concentrations of PFTs in the wells are approximately the same, the barrier is considered intact. On the other hand, if a breach occurs, the concentration of tracer measured in the monitoring wells will be orders of magnitude greater, even for a small hole. The quantity, type, and location of tracer detected on the monitoring side of the barrier indicates the size and location of the breach (i.e., the larger the opening, the greater the amount of tracer detected) (Heiser et al., 1997). The spectra of the tracers passing through the wall is used to identify the location of the breach relative to the tracer injection points. PFTs can be used to detect small holes in the wall as well as slight imperfections. PFTs can "definitely detect a problem, but there is a question of how precisely they can locate the problem in the field" (Terry Sullivan, personal communication). Theoretically, PFTs should be very precise, but realistically, field detection is much less precise than in the laboratory. The thrust of the current work is to determine how precisely PFTs can locate a defect in the barrier.
Advantages
Disadvantages
Cost
The cost of using PFTs depends on the size of the subsurface barrier because the size will dictate the number of samples that need to be collected. An estimated unit cost per sample is about $20. However, this number may be higher or lower depending on the scale of the problem (Terry Sullivan, personal communication).
State of the Technology
Points of Contact
Terry Sullivan
Building 830
Brookhaven National Laboratory
Upton, NY 11973
Phone: 516/344-2840
Fax: 516/344-4486
e-mail: sulliva1@bnl.gov
4.1.2 Science and Engineering Associates, Inc. (SEA)
SEAtraceTM is a subsurface gaseous tracer system developed by Sandia National Laboratories and SEA, Inc. for the detection of leaks in subsurface barriers and liners. The tracer gas sulfur hexafluoride (SF6) is injected into the contained area. As it diffuses through the barrier into the surrounding area, it is detected by a multi-point vapor sampling system (Sandia website). See Figure 8 for a simple diagram of the SEAtraceTM gas tracer monitoring system. The soil analysis is done by a system called MultiScanTM, which automatically samples and analyzes gas and contamination. The tracer concentrations are converted into an inverse optimization code that identifies the size and location of the defect in the wall. Within 30 minutes, the inversion analysis is complete. Although it is more difficult to determine the size of the leak than the location of the breach, the SEAtraceTM system is capable of locating the leak to within 0.5 m and identifying the size of the leak to within 0.15 m (Sandia website).
Figure 8: SEAtraceTM Gas Tracer Monitoring System
Source: Adapted from SEAtracTM , Subsurface Barrier Monitoring and Verificiation
The SEAtraceTM system uses a photoacoustic gas analyzer manufactured by Innova Instruments. The system can measure essentially any gas compound with an infrared absorption spectrum and can be configured to simultaneously analyze five compounds (Bill Lowry, personal communication). This includes all volatile organic compounds, freons, tracer gases such as sulfur hexafluoride, carbon dioxide, and many others. At a particular site, the system can be set to analyze the five dominant contaminants.
Advantages
Disadvantages
Cost
Based on a typical large barrier with a wall area of 42,000 ft2 (SEAtraceTM), the total verification and monitoring cost would be $355,000 (30% for installation and materials, 37% for design and analysis, and 33% for a monitoring system). The unit cost/barrier wall area is $8.45/ft2. However, the cost drops to $7/ft2 if the system is reused at other sites.
State of the Technology
Points of Contact
Bill Lowry
Science and Engineering Associates, Inc.
3205 Richards Lane, Suite A
Santa Fe, NM 87505
Phone: 505/424-6955
Fax: 505/424-6956
e-mail: blowry@seabase.com
http://www.seabase.com
4.1.3 Comparison of PFTs and SEAtraceTM
The following is a comparison of the gas tracers, PFTs and SEAtraceTM:
4.2 Electrical Resistance Tomography (ERT)
Electrical resistance tomography was first identified as a geophysical imaging tool in 1978 and has evolved into a system able to detect leaks from underground storage tanks, monitor subsurface air sparging, and map the movement of contaminant plumes (Daily et al., 1998). ERT uses conduction currents to measure resistivity and produce cross sectional subsurface maps based on images before and after barrier emplacement. To measure the resistivity, a current is passed between two electrodes. The barrier materials are more electrically conductive than the surrounding soils and appear as anomalies on the tomographs (Daily et al., 1998). The barrier wall thickness determines the borehole separation and depth. Thinner walls require the electrodes to be closer together to form the image. ERT can also be used to evaluate the hydraulic conductivity of the barrier.
Advantages
Disadvantages
Cost
The cost of the hardware is approximately $50,000. The cost range for the engineering workstation required for data inversion is $10,000 – $20,000. The cost of licensing the data inversion is project specific (Pacific Northwest National Laboratory website).
State of the Technology
Points of Contact
William Daily
Lawrence Livermore National Laboratory
Livermore, CA 94550
Phone: 925/422-8623
Fax: 925/422-2495
e-mail: daily1@llnl.gov
Abelardo Ramirez
Lawrence Livermore National Laboratory
Livermore, CA
Phone: 925/422-6909
Fax: 925/422-3925
e-mail: ramirez3@llnl.gov
4.3 Ground Penetrating Radar (GPR)
GPR is a geophysical tool that has been in use since the late 1940s and has been of interest in the environmental field since the 1970s. The first applications of GPR occurred in the early 1970s to locate subsurface structures such as mining tunnels and buried waste (Heiser et al., 1997). GPR uses electromagnetic waves to penetrate the surface. A radar antennae is passed along a set of grid lines across a site, and when the waves come into contact with materials in the subsurface, part of the wave energy is reflected back to a receiving station. The changes in radar signal (reflection or absorption) can be used to map the subsurface. The quantity of energy reflected depends on the electrical conductivity encountered along the path (MSE, 1996). The amount of energy reflected, in addition to the travel time, can be used to determine the depth of the obstruction. GPR can potentially be used to verify the emplacement, location, and continuity of a subsurface barrier, as well as track a contaminant plume around a containment facility (Rumer and Mitchell, 1996).
Advantages
Disadvantages
Cost
For specific cost and vendor information see EPA’s Vendor Field Analytical and Characterization Technologies System (VendorFACTS). The database contains information provided by vendors on the application, performance, and use of their products. VendorFACTS is available at http://www.epareachit.org.
State of the Technology
Seismic methods rely on measuring the speed of waves traveling through a specific medium.
Reflection and/or refraction of the wave depends on the physical and chemical properties of the media. The waves can be detected and measured by special sensors. A specific type of seismic technology called crosswell seismic tomography or crosshole seismic imaging places transmitters in one borehole and receivers in another borehole. The time it takes the seismic waves to travel between the transmitter and a receiver is inverted into a two-dimensional map of velocity and structure (Rumer et al., 1996). Seismic wave velocity is proportional to the density of the media. Seismic methods use velocity to evaluate the integrity of a subsurface barrier by comparing time measurements before and after grouting. Resolution varies with frequency such that higher frequency waves provide better resolution. The technology is similar to GPR except that it uses different energy frequencies and a different energy source (MSE-TA, unpublished).
Advantages
Disadvantages
State of the Technology
4.5 Electro-Acoustics (or Seismo-Electrics)
Electro-acoustics is a subsurface imaging technology combining electrical and acoustical methods. The detection capabilities are better than either electric or acoustic methods alone (MSE, 1996). This imaging technique emits an acoustic pulse that is detected as an electrical signal. The acoustic waves interact with the electrical structure of the medium (MSE, 1996).
State of the Technology
4.6 Slurry Wall Monitoring (Germany)
In Germany, a new geoelectrical technology is being tested for locating heterogeneities and/or leakage zones in slurry walls. This technology involves the placement of vertical chains within the slurry wall during construction to identify regions of high permeability within the wall. Deciding where to position individual electrodes (vertically and horizontally) is based on site-specific considerations. Each electrode can measure electrical potential and introduce electrical current.
Advantages
Disadvantages
State of the Technology
Cost
The cost of the geoelectrical system is about 5% of the total cost of the slurry wall (Heike Bradl, personal communication).
Points of Contact
Heike Bradl
Research and Development
Bilfinger + Berger Bauaktiengesellschaft
Carl-Rei-Platz 1-5
D-68 165 Mannheim GERMANY
Phone: +49-621/459-2613
Fax: +49-621/459-2350
e-mail: fue.bilberg@t-online.de
4.7 Monitoring of Slurry Walls in the United Kingdom
Barrier wall technology is widely accepted in the United Kingdom (UK) and Europe. Cement-bentonite walls are the most common types of containment barrier used in the UK. According to Stephan Jefferis, there is an assumption that if the wall is constructed or installed as specified, it should work. Thus, monitoring is not a primary concern to industry or the regulatory agencies in the UK (personal communication). The typical method the UK uses for long-term monitoring consists of sampling the slurry and then allowing it to set. This method is based on the assumption that the characteristics of the slurry are representative of the wall.
Probes have also been inserted into the slurry wall for long-term monitoring. This technique has been tested three times, and in each case, the technique was unsuccessful (Stephan Jefferis, personal communication). Cement-bentonite is very brittle and tends to crack when probes are inserted. Since soil bentonite is less brittle, probes containing this material might not damage the wall.
Test boxes are another type of monitoring technique used occasionally in the UK. This technology involves digging a trench the length of the wall and putting a loop in the wall. The box is then placed along the line of the wall. Three or four test boxes have been used in the UK and all tests have been satisfactory (Stephan Jefferis, personal communication). The first box installed was 2 m by 10 m and the second box was 6 m by 4 m. The slurry wall forms one side of the box. Monitoring wells are placed around and inside the box. The box traps the groundwater, which can then be tested for contaminants. Because groundwater flow is slow, it takes a long time (three months) to get enough water to run the tests. Single or multiple boxes could potentially be used for long-term monitoring. In Austria, boxes were placed between a pair of thin walls forming a continuous row of boxes. The main limitation of this technology is the expense.
The main question with slurry wall emplacement is whether the wall reached full base (fully emplaced). If problems are suspected, good construction records should help identify potentially weak areas of the wall (Stephan Jefferis, personal communication). The materials can be tested in the laboratory, but when monitoring the performance and integrity of the wall, it is important to "test" the entire wall. There is a growing interest in the UK in standardizing remedial activities.
Points of Contact
Golder Associates (UK) Ltd.
Stephan Jefferis
54-70 Moorbridge Road
Maidenhead
Berkshire SL6 8BN England UK
Phone: +44-1626/770699
e-mail: sjefferis@golder.com
Appendix A: Matrix for Evaluating Barrier CQA/CQC
Matrix for Evaluating Barrier CQA/CQC Against Acceptable Industry Practices
|
|||
Category |
Less than Acceptable |
Acceptable |
Better than Acceptable |
---|---|---|---|
Specialty Contractor Experience |
< 4 |
4-6 Comparable Projects |
> 6 |
Trench Excavation Methods |
No Inspection |
Periodic Inspections |
Constant Inspection |
Trench, Verticality & Continuity* |
No Inspection |
Periodic Inspection |
Measured |
Trench Sounding (slope & bottom) |
> 20 ft |
per 10-20 ft |
< 10 ft |
Trench bottom Cleaning |
None |
Yes* |
> |
Trench Key Confirmation |
No Sampling |
Sampling every 20 ft |
Sampling < 20 ft |
Slurry Mixing |
< |
Agitation > 12 hrs. Hydration |
> |
Slurry Viscosity Testing |
< 2 |
2 per shift |
> 2 |
Slurry Viscosity |
< 40 |
40+ seconds (marsh funnel) |
40-50 seconds (marsh funnel) |
Slurry Sand Content Tests |
< 2 |
2 per shift |
> 2 |
Slurry Sand Content |
> 15% |
< 15% |
< 15% |
Backfill Slump Testing |
< |
1 per 400-600 cy |
> |
Backfill Slump |
< 3'' or > 6'' |
Most tests 3''- 6'' |
All tests 3'' - 6'' |
Backfill Gradation Testing |
< 1 |
1 per 400-600 cy |
> 1 |
Backfill Permeability Testing |
< 1 |
1 per 400-600 cy |
> 1 |
Backfill Target Permeability |
> |
5 x 10-7 - 1 x 10-7 cm/sec |
< |
Backfill Mixing/placement |
Loosely Controlled |
Controlled Mix/Place |
Central Mix/Guided |
Barrier Continuity |
Interrupted |
Continuous |
Continuous & Confirmed |
Post Construction Barrier Sampling/Testing |
None |
Minimal |
Regular & Documented |
As-Built Records |
None |
Construction Completion Report |
Report, Drawings, Test Results |
Groundwater Head Monitoring |
None |
Monitored Fluctuation |
Periodic & Across Barrier |
Final Barrier Alignment Survey |
None |
Surveyed |
Surveyed & Monumented |
Barrier Construction Specification |
None |
Barrier |
Barrier & CQA Plan |
CQA/CQC Program and Testing Specification |
None |
Designer Specified |
Independent Duplicate QA |
Groundwater Chemistry Monitoring |
None |
Minimal |
Periodic & Across Barrier |
Source: EPA, 1998 *Observation of trench width and equipment verticality
Note: The categories, slurry sand content and backfill slump, are site-specific, and the numbers given above are typical for soil-bentonite slurry walls.
Groutability, which is the ability of soil to receive grout, depends on the permeability of the soil and the viscosity of the grout. Soils with permeabilities less then 10-6 cm/s are not amenable to grout, and soils with permeabilities greater than 10-1 cm/s require suspension grouts or chemical grouts containing filler materials (Mutch et al., 1997). Gravels and sands tend to be groutable while soils containing more than 20% silt are not usually receptive to grout (Montan Wax, 1995). Silts and clays are difficult or impossible to grout (Voss et al., 1994). There is a relationship between viscosity and soil permeability. Typically, higher viscosity grouts are better suited to high permeability soils (i.e., soils with larger void spaces), and low viscosity grouts are necessary when the soil has a low permeability (Voss et al., 1994). See Tables B-1 and B-2.
Table B-1: Relationship Between Soil Permeability and Groutability
Permeability (cm/sec) |
Groutability |
---|---|
£ 10-6 |
Ungroutable |
10-5 to 10-6 |
Groutable with difficulty by grouts with viscosity < 5 cP Ungroutable with grouts having viscosity > 5 cP |
10-3 to 10-6 |
Groutable with low viscosity grouts, but difficult with grouts with a viscosity > 10 cP |
10-1 to 10-3 |
Groutable with all commonly used chemical grouts |
³ 10-1 |
Requires suspension grouts or chemical grouts containing a filler material |
Source: Karol 1990 in Voss et al., 1994
Table B-2: Compatibility Between Soil Matrix and Grout
Allan, M.L. and L.E. Kukacka. 1995. "Analysis of Core Samples from Jet Grouted Soil." Prepared for Sandia National Laboratories, BNL-62357.
Allan, M.L. and L.E. Kukacka. 1995. "Permeability of Microcracked Fibre Reinforced Containment Barriers." Waste Management, Vol. 15, No. 2, pp. 171-177.
Allan, M.L. and L.E. Kukacka. 1993. "In-Situ Containment and Stabilization of Buried Waste." Annual Report FY 1993, BNL 49709.
Barrier Containment Corporation. "EnviroWallTM Installation Report." Prepared by Argonne National Laboratory under contract number 942352401 for the U.S. Department of Energy.
Burgess, A.S. 1995. "New Barrier Technologies on the Horizon." International Ground Water Technology, Vol. 1, No. 12, pp. 23-24.
Burson, B., A. Baker, B. Jones, and J. Shailer. 1997. "Developing and Installing a Vertical Containment System." Geotechnical Fabrics Report.
Campbell, B.E., J.E. Hansen, and C.L. Timmerman. 1996. "In Situ Vitrification (ISV): An Evaluation of Contaminant Species During Thermal Processing." A paper presented at the Fifteenth International Conference on Incineration and Thermal Treatment Technologies, Savannah, Georgia.
Daily, W. and A. Ramirez. June 1998. "Electrical Imaging of Engineered Hydraulic Barriers." Lawrence Livermore National Laboratory.
Day, S. 1994. "The Compatibility of Slurry Cutoff Wall Materials with Contaminated Groundwater." ASTM special technical publication.
Dietrich, P., T.H. Fechner, H.B. Bradl, and H. Scad. 1997. "A New Technology for Quality Assessment of Slurry Walls." Field Screening Europe, 61-64.
Dunn, M.J. 1994. "In-Situ Remediation of Contaminated Ground Water Using the Mag*SepSM Technology." Hanford Symposium on Health and the Environment, Pasco, Washington.
Dwyer, B.P. 1994. "Feasibility of Permeation Grouting for Constructing Subsurface Barriers." SAND94-0786.
Dwyer, B.P. 1998. "Treatment of Mixed Contamination in Complex Hydrogeologic Settings."Sandia National Laboratories.
Dwyer, B.P., J. Heiser, W. Stewart, and S. Phillips. 1997. "In-Situ Containment of Buried Waste at Brookhaven National Laboratory." International Containment Technology Conference and Exhibition Proceeding, St. Petersburg, FL, February 9-12.
Edil, T.B., J.K. Park, and D.P. Heim. 1994. "Large Test Size for Transport of Organics Through Clay Liners." ASTM STP 1142, 353.
"Environmental Damage Limited by Wax Injection." 1993. Colliary Guardian. FMJ International Publications Ltd., England, pp. 68-70.
"EnviroWallTM Innovative Technology for Remedial Applications and Containment Structures," brochure.
FlowTex and Romanta. 1997. "Sealing Waste Disposals with Flowmonta."
Giroud, J.P., K.L. Soderman, and K. Badu-Tweneboah. 1997. "Optimal Configuration of a Double Liner System Including a Geomembrane Liner and a Composite Liner." Geosynthetics International, Vol. 4, Nos. 3-4, pp. 373-389.
Global Environment and Technology Foundation (GETF). 1996. "Market Assessment Protective Underground Barrier Technologies." prepared for the U.S. Department of Energy.
Golder Associates Inc., 1993. "Laboratory Test Results for Evaluating the Performance of Montan Wax and Sodium Silicate Barrier Materials in Unconsolidated Soils."
Golder Associates Inc., 1994. "Preliminary Results of Permeation Tests using Montan Wax and Sodium Silicate Barrier Materials in Unconsolidated Soils at the Mixed Waste Landfill Integrated Demonstration Site (MWLID)." Report number 913-1248.600b.
Groundwater Control Inc., brochure.
Heiser, J.H. and B. Dwyer. 1997. "Summary Report on Close-Coupled Subsurface Barrier Technology Initial Field Trials to Full-Scale Demonstration." Brookhaven National Laboratory, BNL-52531.
"Installation of Barrier Member Containment Corporation’s EnviroWallTM System." Prepared by the University of Chicago as Operator of Argonne National Laboratory under contract number W-31-109-ENG-38.
Jefferis, S.A. 1992. "Remedial Barriers and Containment." Contaminated Land Treatment Technologies. Ed. John F. Rees. London.
Jefferis, S.A. 1997. "European Quality Assurance and Quality Control for Cut-Off Walls and Caps." International Containment Technology Conference and Exhibition Proceeding, St. Petersburg, FL, February 9-12.
Jessberger, H.L., ed. 1991. "Geotechniques of Landfills and Contaminated Land, Technical Recommendations." European Technical Committee, ETC 8, Ernst and Sohn, Berlin, Germany.
Karol, R.H. (1990). "Chemical Grouting." Marcel Dekker, New York.
Kim, J.Y., J.K. Park, and T.B. Edil. 1997. "Sorption of Organic Compounds in the Aqueous Phase Onto Tire Rubber." Journal of Environmental Engineering, Vol. 123, No. 9, pp. 827-835.
"Montan Wax and Sodium Silicate Grout Materials Tested as Containment Barriers." September/October 1995. The Hazardous Waste Consultant.
Moridis, G., J. Apps, P. Persoff, L. Myer, S. Muller, P. Yen, and K. Pruess. 1996. "A Field Test of a Waste Containment Technology Using a New Generation of Injectable Barrier Liquids." Spectrum’96, Seattle, WA (August 18-23, 1996). Lawrence Berkeley National Laboratory Report LBNL-38817, Berkeley, CA.
Molony, H.D. and T.J. Crocker. 1998. "Design and Proof-of-Principle Testing of a Buried Waste Containment System." Final Report, RAHCO International.
Moridis, G., P. Yen, P. Persoff, S. Finsterle, P. Williams, L. Myer, and K. Pruess. September, 1996. "A Design Study for a Medium-Scale Field Demonstration of the Viscous Barrier Technology." Lawrence Berkeley National Laboratory, LBNL-38916.
Moridis, G., P. Persoff, J. Apps, A. James, C. Oldenberg, A. McGrath, L. Myer, L. Pellerin, and K. Pruess. November, 1996. "A Design Study for the Isolation of the 281-3H Retention Basin a the Savannah River Site Using the Viscous Barrier Technology." Lawrence Berkeley National Laboratory, LBNL-38920.
Morris, C.E., B.M. Thomson, and J.C. Stormont. 1995. "Assessment of Dry Barriers for Containment of Mobile Constituents in the Unsaturated Zone." Sandia National Laboratory, SAND94-2094.
Morris, C.E., B.M. Thomson, and J.C. Stormont. In press, 1998. "Design of Dry Barriers for Containment of Contaminants in Unsaturated Soils." Ground Water Monitoring and Remediation.
MSE Technology Applications, Inc. 1996. "Subsurface Barriers Monitoring and Verification Technologies Strategic and Implementation Plan." Vol. 1.
Muhlbaier, D.R., Strategic Environmental and Development Program (SERDP). 1997. "Horizontal Subsurface Barrier (HSSB) for In Situ Remediation of Organically Contaminated Soils and Groundwater."
Muhlbaier, D.R. and G.M. Powers. 1997. "In Situ Horizontal Subsurface Barrier Technology for Soil Remediation."
Mutch, R.D., R.E. Ash, and J.R. Caputi. 1997. "Contain Contaminated Groundwater." Chemical Engineering, Vol. 104, No. 5, pp. 114-119.
Park, J.K., J.Y. Kim, and T.B. Edil. 1996. "Mitigation of Organic Compound Movement in Landfills by Shredded Tires." Water Environment Research, Vol.68, No. 1, pp. 4-10.
Park, J.K., J.Y. Kim, C.D. Madsen, and T.B. Edil. 1997. "Retardation of Volatile Organic Compound Movement be a Soil-Bentonite Slurry Cutoff Wall Amended With Ground Tires." Water Environment Research, Vol., 69, No. 5, pp. 1022-1030.
Pringle, S., C.E. Morris, B. Thomson, and J. Stormont. 1995. "Tensiometric Barriers for Containment at Waste Sites." International Journal of Environmentally Conscious Design and Manufacturing, Vol. 4. No. 3-4.
Roberds, W. and A. DuCharme. 1992. "Evaluation of Grouting Technology: DOE Perspective." Presented at the EPA 4th Forum on Innovative Hazardous Waste Treatment Techniques, San Francisco, CA.
Rumer, R.R. and J.K. Mitchell, eds. 1996. "Assessment of Barrier Containment Technologies A Comprehensive Treatment for Environmental Remedial Application." Product of the International Containment Technology Workshop. National Technical Information Service, PB96-180583.
Rumer, R.R. and M.E. Ryan, eds. 1995. "Barrier Containment Technologies for Environmental Remediation Applications." Product of the International Containment Technology Workshop. John Wiley and Sons, Inc., New York.
Sass, I., O. Caldonazzi, and T. Beyer. 1997. "The Application of Flowmonta for Environmental Problems." International Containment Technology Conference and Exhibition Proceeding, St. Petersburg, FL, February 9-12.
Smyth, D.J.A., J.A. Cherry, and R.J. Jowett. 1995. "Sealable Joint Steel Sheet Piling (Waterloo BarrierTM) for Groundwater Pollution Control." Presented at the International Containment Technology Workshop, Baltimore, Md.
Sullivan, T.M., J. Heiser, A. Gard, and G. Senum. 1998. "Monitoring Subsurface Barrier Integrity Using Perfluorocarbon Tracers." Journal of Environmental Engineering, Vol. 124, No. 6, pp. 490-497.
Tallard, G. 1997. "Very Low Conductivity self-hardening Slurry for Permanent Enclosures." International Containment Technology Conference and Exhibition Proceeding, St. Petersburg, FL, February 9-12.
Thomson, B.M., C.E. Morris, J.C. Stormont, and M.D. Ankeny. 1996. "Development of Tensiometric barriers for Containment and Remediation at Waste Sites." Radioactive Waste Management and Environmental Restoration, Vol. 20, pp. 167-189.
Thomson, B.M., C.E. Morris, J.C. Stormont, and M.D. Ankeny. 1994. "Development of Tensiometric Barriers for Containment and Remediation at Waste Sites." Proceedings from the Symposium on Waste Management, Tucson, Arizona.
U.S. Army Corps of Engineers. 1994. "Soils-Bentonite Slurry Trench for HTRW Projects." Department of Army, Washington, DC CEGS-02444.
U.S. Army Corps of Engineers. 1995. "Checklist for Design of Vertical Barrier Walls for Hazardous Waste Sites." Department of the Army, Washington, DC ETL 1110-1-158.
U.S. Environmental Protection Agency. 1998. "Evaluation of Subsurface Engineered Barriers at Waste Sites." EPA 542/R-98/005.
U.S. Environmental Protection Agency. 1993. "Quality Assurance and Quality Control for Waste Containment Facilities." EPA 600/R-93/182.
U.S. Environmental Protection Agency. 1992. "Construction Quality Management for Remedial Action and Remedial Design Waste Containment Systems." EPA 540/R-92/073.
U.S. Environmental Protection Agency. 1992. "Engineering Bulletin Slurry Walls." EPA 540/S-92/008.
U.S. Environmental Protection Agency. 1987. "Construction Quality Control and Post-Construction Performance Verification for the Gilson Road Hazardous Waste Site Cutoff Wall." EPA 600/2-87/065.
Voss, C.F., C.M. Einberger, and R.V. Matalucci. 1994. "Evaluation of Two New Grouts for Constructing Subsurface Barriers." Hanford Symposium on Health and the Environment, Pasco, Washington.
Voss, C.F., O. Caldonazzi, and K. Pertl. 1993. "Evaluation of a Montan-Wax Emulsion for Constructing Subsurface Barriers." ER’93 Environmental Remediation Conference, Augusta, GA, October 24-28.
Wilson, D.D. 1995. "Barrier Technology is Waxing for Recalcitrant Sites." Ground Water Monitoring and Remediation.